A total of 270 crowns were evaluated, including 90 SLM metal-cera

A total of 270 crowns were evaluated, including 90 SLM metal-ceramic crowns (group B), 90 zirconium-oxide-based ceramic crowns (group L), and 90 lithium disilicate ceramic crowns (group C). The marginal and internal gaps of the crowns were recorded using a replica technique with a silicone indicator paste stabilized with a light-body silicone. The gap replica specimen were sectioned buccolingually and

mesiodistally and then examined using a stereomicroscope at 30× magnification. Ten reference points were measured on each anterior and premolar specimen, and 20 reference points were measured on each molar specimen. Two-way ANOVA was performed to identify the significant differences between the groups. The mean marginal fit of group B was significantly better than those of group C selleck kinase inhibitor and group L (p < 0.005), but a significant difference was not found between group C and group L (p > 0.05). The mean axial gap of group B was significantly smaller than those of group C and group L (p < 0.01), while group

C was not different from group L (p > 0.05). The mean occlusal gap of group B was significantly higher than those of group C and group L (p < 0.05), and no difference was found between group C and group L (p > 0.05). The marginal and internal gaps of crowns varying according to tooth type were not significantly different (p > 0.05). The SLM system demonstrated better marginal and internal this website fit compared to the two CAD/CAM grinding systems examined. Tooth type did not significantly influence the marginal or internal fit. “
“Purpose: This study evaluated the effect of anchorage

on the accuracy of fit in removable partial denture framework. Materials and Methods: Twenty-four partially edentulous maxillary refractory O-methylated flavonoid casts were duplicated from a machine-milled metal cast. Twelve of these were included in the test group, which had the provision for anchorage in the refractory cast, and the remaining 12 were taken as control group, which did not have provision for anchorage. Identical wax patterns for the maxillary strap major connector were invested and cast in cobalt chromium alloy. The accuracy of fit of the cast partial major connector frameworks were measured at two selected points using a profile projector. The resultant data were analyzed using student’s t-test and unpaired t-test. Results: Student’s t-test showed statistically significant improvement in the fit of the major connectors of the test group at point A (p= 0.0003) and P (p= 0.0074). Unpaired t-test was performed for the control and test group. The results of the unpaired t-test for the control group exhibited a greater gap discrepancy (0.44 ± 0.20 mm) than for the test group at point A (0.16 ± 0.10 mm). Similarly, the gap was more at Point P for the specimens in the control group (0.65 ± 0.10 mm) than the test group (0.42 ± 0.24 mm).

Comments are closed.